{"title":"Anorectal Manometry Balloon Expulsion Test","description":"Balloon expulsion test components for anorectal manometry assessments in colorectal and gastroenterology settings. Compatible with standard manometry systems for pelvic floor evacuation studies.","products":[{"product_id":"anorectal-expulsion-balloon-catheter-sr2b","title":"Anorectal Expulsion Balloon Catheter - SR2B Filled with Air\/Water","description":"\u003cp\u003eThe SR2B is a single‑use anorectal expulsion balloon catheter for Balloon Expulsion Test (BET), rectal balloon therapy, and anorectal manometry using air or water. It helps GI motility labs and pelvic floor therapists standardize testing in patients with chronic constipation, dyssynergic defecation, fecal incontinence, and other defecatory disorders. It includes a stopcock and syringe.\u003c\/p\u003e\n\u003ch2\u003eKey features and benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible air \u003cstrong\u003eor\u003c\/strong\u003e water inflation so you can follow either air‑based or water‑based BET and rectal balloon therapy protocols with a single catheter.\u003c\/li\u003e\n\u003cli\u003eNon‑latex, non‑DEHP balloon with up to 400 mL capacity and printed volume marks to standardize inflation and reduce the risk of over‑distension or mucosal trauma.\u003c\/li\u003e\n\u003cli\u003eSingle‑use, EO‑sterile design that removes reprocessing steps and supports infection‑control policies in motility labs and pelvic floor clinics.\u003c\/li\u003e\n\u003cli\u003eSpecially designed flexible tubing and clear markings for easy placement and more consistent positioning across operators and visits.\u003c\/li\u003e\n\u003cli\u003eWorks with solid‑state or water‑perfused motility systems using standard syringes and stopcocks (included), fitting smoothly into existing lab setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eClinical indications and use cases\u003c\/h2\u003e\n\u003cp\u003eTypical patients include adults with chronic constipation, suspected dyssynergic defecation, pelvic floor dysfunction, or fecal incontinence referred for anorectal manometry or biofeedback‑based rectal balloon training.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBalloon Expulsion Test to assess whether patients can expel a simulated stool, helping identify outlet obstruction and dyssynergic defecation.\u003c\/li\u003e\n\u003cli\u003eRectal balloon therapy and biofeedback for defecation training, sensory training, and urge‑resistance or coordination programs in fecal incontinence.\u003c\/li\u003e\n\u003cli\u003eAnorectal manometry and rectal compliance testing where controlled inflation volumes with air or water are needed to guide treatment decisions.\u003c\/li\u003e\n\u003cli\u003ePelvic floor physical therapy programs that integrate rectal balloon work as a first‑line or adjunctive tool in pelvic floor dysfunction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow the SR2B is used\u003c\/h2\u003e\n\u003cp\u003eIn a standard BET, the lubricated SR2B is inserted into the rectum, the balloon is inflated with a set volume of air or water (often around 30–60 mL), and the patient is asked to expel the balloon while you record the time and symptoms. This simulates a bowel movement and helps determine whether the patient has difficulty evacuating stool.\u003c\/p\u003e\n\u003ch2\u003eHow SR2B compares to other catheters\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSR1B\u003c\/strong\u003e: Single‑use catheter for air‑only protocols, used for BET and related anorectal procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSR2B\u003c\/strong\u003e: Single‑use catheter that offers the same 400 mL balloon volume as SR1B but allows either air or water inflation, giving labs more flexibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCR1B\u003c\/strong\u003e: Reusable air‑only catheter that requires cleaning and reprocessing (up to 50 times) between patients according to IFU.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eChoose SR2B when you want the convenience of single‑use plus the option to run either air‑based or water‑based BET and rectal balloon therapy across different programs and sites.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003c!-- Responsive table wrapper --\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSR2B specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended use\u003c\/td\u003e\n\u003ctd\u003eSingle‑use PVC manometric catheter for Balloon Expulsion Test, rectal balloon therapy, anorectal manometry, and rectal compliance testing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInflation medium\u003c\/td\u003e\n\u003ctd\u003eBalloon can be used with air or water, commonly 30–60 mL during BET or rectal balloon training as per protocol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalloon material\u003c\/td\u003e\n\u003ctd\u003eMedical‑grade PVC, non‑latex, non‑DEHP 400 mL balloon.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalloon capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 400 mL volume with printed volume marks to guide standardized inflation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTubing design\u003c\/td\u003e\n\u003ctd\u003eFlexible tubing engineered for patient comfort and easy handling during rectal balloon procedures.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlacement markings\u003c\/td\u003e\n\u003ctd\u003eLength markings to support consistent balloon positioning in the rectum.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility and use\u003c\/td\u003e\n\u003ctd\u003eEO‑sterile, single‑patient use only; do not re‑sterilize or reuse.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem compatibility\u003c\/td\u003e\n\u003ctd\u003eCan be used with solid‑state or water‑perfused motility systems with compatible syringes and stopcocks (included).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- End responsive table wrapper --\u003e\n\u003ch2\u003eOrdering information\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code: SR2B – Anorectal Expulsion Balloon Catheter, air or water, single‑use PVC manometric catheter.\u003c\/li\u003e\n\u003cli\u003ePackaging: 10 catheters per box.\u003c\/li\u003e\n\u003cli\u003eRelated products: SR1B (single‑use, air only), CR1B (reusable, air only) – see related product pages for full details.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRegulatory and safety information\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for single use in appropriately trained clinical settings to support anorectal balloon expulsion and motility testing.\u003c\/li\u003e\n\u003cli\u003eFollow institutional protocols and the Instructions for Use, and discard the catheter after each procedure according to local regulations for contaminated medical waste.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003ch3\u003eWhat is the SR2B used for?\u003c\/h3\u003e\n\u003cp\u003eThe SR2B is used for Balloon Expulsion Test, rectal balloon therapy, anorectal manometry, and rectal compliance studies in patients with suspected defecatory disorders or pelvic floor dysfunction.\u003c\/p\u003e\n\u003ch3\u003eCan the SR2B be used with both air and water?\u003c\/h3\u003e\n\u003cp\u003eYes, the SR2B balloon can be filled with either air or water, typically around 30–60 mL depending on your protocol, so you can match your preferred equipment and lab workflow.\u003c\/p\u003e\n\u003ch3\u003eIs the SR2B catheter single‑use?\u003c\/h3\u003e\n\u003cp\u003eYes, the SR2B is a single‑use, EO‑sterile catheter and must be discarded after each patient; it is not intended to be reprocessed or re‑sterilized.\u003c\/p\u003e\n\u003cp\u003eReady to add the SR2B Anorectal Expulsion Balloon Catheter to your GI motility or pelvic floor therapy program?\u003c\/p\u003e","brand":"Mui Scientific","offers":[{"title":"10\/bx \/ Anorectal Balloon Catheters","offer_id":45031325204616,"sku":"SR2B","price":550.0,"currency_code":"USD","in_stock":true},{"title":"ea \/ Anorectal Balloon Catheters","offer_id":45067545739400,"sku":"SR2B-EA","price":65.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/4094\/5544\/files\/Expulsion-Balloon-Catheter_5311.jpg?v=1776912514"},{"product_id":"anorectal-expulsion-balloon-catheter-reusable","title":"Anorectal Expulsion Balloon Catheter Reusable","description":"\u003cp\u003eThe CR1B is a reusable anorectal expulsion balloon catheter for the Balloon Expulsion Test (BET) and balloon-based biofeedback using air inflation. One catheter can be cleaned, high-level disinfected and reused for up to 50 procedures, making it a cost-effective option for GI motility labs and pelvic floor therapy programs that test or train patients with chronic constipation, dyssynergic defecation, fecal incontinence and other defecatory disorders.\u003c\/p\u003e\n\u003ch2\u003eKey features and benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReusable for up to 50 procedures or 5 years, whichever comes first, when reprocessed according to the Instructions for Use (IFU) — one catheter, not 50.\u003c\/li\u003e\n\u003cli\u003eNon-latex, non-DEHP balloon with up to 400 mL capacity for air-based BET and rectal balloon therapy protocols.\u003c\/li\u003e\n\u003cli\u003eMarkings for balloon placement to support consistent positioning across operators and visits.\u003c\/li\u003e\n\u003cli\u003eSpecially designed flexible tubing for easy intubation and patient comfort.\u003c\/li\u003e\n\u003cli\u003eCan be used with solid-state or water-perfused motility systems and with handheld biofeedback devices through a standard 3-way stopcock and extension tube.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eClinical indications and use cases\u003c\/h2\u003e\n\u003cp\u003eThe CR1B is indicated when there is a need to evaluate a suspected anorectal disorder. Typical patients include adults with chronic constipation, suspected dyssynergic defecation, pelvic floor dysfunction or fecal incontinence referred for anorectal function testing or biofeedback-based rectal balloon training.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBalloon Expulsion Test to assess whether patients can expel a simulated stool, helping identify impaired evacuation and dyssynergic defecation alongside anorectal manometry.\u003c\/li\u003e\n\u003cli\u003eRectal balloon therapy and biofeedback for defecation training, sensory training, and urge-resistance or coordination programs in fecal incontinence.\u003c\/li\u003e\n\u003cli\u003ePressure biofeedback with handheld devices, where the patient's squeeze pressure is displayed while the air-filled balloon is in place.\u003c\/li\u003e\n\u003cli\u003ePelvic floor physical therapy programs that use rectal balloon work repeatedly and want a reusable alternative to single-use catheters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow the CR1B is used\u003c\/h2\u003e\n\u003cp\u003eFor a balloon expulsion test, the CR1B is lubricated with a water-based lubricant and inserted 8–10 cm into the rectum. A 3-way stopcock is attached, the balloon is filled with 30–60 mL of air, the port is closed and the syringe removed. The patient then attempts to expel the catheter on a toilet or commode while you record the time and symptoms; per the IFU, expulsion within 2–5 minutes indicates normal function. Fill the CR1B with air only — water can cause balloon detachment or rupture.\u003c\/p\u003e\n\u003cp\u003eFor biofeedback, the catheter, a syringe and an extension tube are connected through the 3-way stopcock, the extension tube is attached to the handheld biofeedback device, and the balloon is filled with 30–60 mL of air. Each use should not exceed 30 minutes inside the gastrointestinal tract.\u003c\/p\u003e\n\u003ch2\u003eHow CR1B compares to other catheters\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCR1B\u003c\/strong\u003e: Reusable, air-only catheter that requires cleaning and high-level disinfection between patients according to the IFU, for up to 50 uses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSR1B\u003c\/strong\u003e: Single-use catheter for air-only protocols, used for BET and related anorectal procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSR2B\u003c\/strong\u003e: Single-use catheter with the same 400 mL balloon volume that allows either air or water inflation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eChoose CR1B when your program runs air-based BET or rectal balloon therapy regularly and has a validated reprocessing workflow. If your protocol uses a water-filled balloon, choose the SR2B instead.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003c!-- Responsive table wrapper --\u003e\n\u003cdiv style=\"overflow-x:auto; -webkit-overflow-scrolling:touch; max-width:100%;\"\u003e\n\u003ctable style=\"min-width:480px; width:100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eCR1B specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended use\u003c\/td\u003e\n\u003ctd\u003eReusable PVC manometric catheter that isolates the anorectal balloon function, used to evaluate the muscular contractions of the rectum (Balloon Expulsion Test and biofeedback).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInflation medium\u003c\/td\u003e\n\u003ctd\u003eAir only, typically 30–60 mL per protocol. Do not fill with water.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalloon\u003c\/td\u003e\n\u003ctd\u003eNon-latex, non-DEHP balloon, maximum volume 400 mL.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials\u003c\/td\u003e\n\u003ctd\u003eContains PVC, polycarbonate, polyisoprene or polyolefin, and silk sutures.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTubing design\u003c\/td\u003e\n\u003ctd\u003eFlexible tubing designed for easy intubation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlacement markings\u003c\/td\u003e\n\u003ctd\u003eMarkings to support consistent balloon positioning in the rectum.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility and reuse\u003c\/td\u003e\n\u003ctd\u003eSupplied non-sterile. Reusable after cleaning and high-level disinfection per the IFU.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice lifetime\u003c\/td\u003e\n\u003ctd\u003eUp to 50 uses or 5 years, whichever comes first; maximum 30 minutes inside the GI tract per use. The user tracks age and number of uses.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eClean, dry location; 15–30 °C (60.8–80.6 °F); 10–75% humidity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem compatibility\u003c\/td\u003e\n\u003ctd\u003eCan be used with solid-state or water-perfused motility systems and handheld biofeedback devices via a 3-way stopcock (luer connection).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- End responsive table wrapper --\u003e\n\u003ch2\u003eCleaning, disinfection and storage\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClean immediately after each procedure: attach and close the stopcock so no liquid enters the balloon, wash in warm water with an enzymatic detergent, rinse with clean water and wipe the external surface.\u003c\/li\u003e\n\u003cli\u003eHigh-level disinfect by fully submerging the catheter (stopcock closed) in a compatible disinfectant according to the disinfectant manufacturer's instructions. The IFU lists Sporox, Korsolex Extra, OPTIM CS and Adaspor Plus Ready to Use as compatible.\u003c\/li\u003e\n\u003cli\u003eDo not use Cidex products, do not soak in alcohol and do not steam autoclave.\u003c\/li\u003e\n\u003cli\u003eRinse with sterile water, wipe dry and store in a clean, dry location.\u003c\/li\u003e\n\u003cli\u003eUse water-based lubricants only; silicone-based lubricants should not be used on the balloon.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering information\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code: CR1B – Anorectal Expulsion Balloon Catheter, reusable, air only, PVC manometric catheter.\u003c\/li\u003e\n\u003cli\u003ePackaging: sold individually (1 catheter, rated for up to 50 uses).\u003c\/li\u003e\n\u003cli\u003eRelated products: SR1B (single-use, air only), SR2B (single-use, air or water) – see related product pages for full details.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRegulatory and safety information\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFor use only under medical supervision by personnel trained in gastrointestinal manometry and anorectal testing.\u003c\/li\u003e\n\u003cli\u003eContraindicated in the presence of any rectal stenosis, structural deformity or disease that increases the risk of distention, perforation or other adverse consequences.\u003c\/li\u003e\n\u003cli\u003eInspect the catheter and packaging before each use and do not use if damaged. Do not alter or modify the catheter, and do not use it beyond its validated lifetime or number of uses.\u003c\/li\u003e\n\u003cli\u003eFollow institutional protocols and the Instructions for Use, and dispose of the catheter at end of life according to local regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003ch3\u003eWhat is the CR1B used for?\u003c\/h3\u003e\n\u003cp\u003eThe CR1B is used for the Balloon Expulsion Test and balloon-based biofeedback in patients with suspected defecatory disorders, dyssynergic defecation, fecal incontinence or pelvic floor dysfunction.\u003c\/p\u003e\n\u003ch3\u003eHow many times can the CR1B be reused?\u003c\/h3\u003e\n\u003cp\u003eOne CR1B catheter can be reused for up to 50 procedures or 5 years, whichever comes first, provided it is cleaned and high-level disinfected between patients according to the IFU. Your facility tracks the number of uses.\u003c\/p\u003e\n\u003ch3\u003eCan the CR1B be filled with water?\u003c\/h3\u003e\n\u003cp\u003eNo. The CR1B is an air-only catheter; filling it with water risks balloon detachment or rupture. For water-filled protocols, use the single-use SR2B.\u003c\/p\u003e\n\u003cp\u003eReady to add the CR1B Reusable Anorectal Expulsion Balloon Catheter to your GI motility or pelvic floor therapy program?\u003c\/p\u003e\n","brand":"Mui Scientific","offers":[{"title":"ea \/ Anorectal Balloon Catheters","offer_id":45067545575560,"sku":"CR1B","price":390.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/4094\/5544\/files\/Expulsion-Balloon-Catheter_5311_3b86cba9-2461-41e1-8c2f-43e42d4c9b45.jpg?v=1776912505"},{"product_id":"anorectal-expulsion-balloon-catheter","title":"Anorectal Expulsion Balloon Catheter - SR1B Filled with Air","description":"\u003cp\u003eThe MUI anorectal balloon catheter is an advanced rectal catheter with balloon design, enabling accurate rectal ballooning and expulsion testing by gastrointestinal specialists, or pelvic floor therapists. This sterile, single-use rectal tube balloon device supports both diagnosis and therapeutic biofeedback in clinical motility settings. It includes a stopcock and syringe.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2 id=\"features-benefits--clinical-use-cases\"\u003eFeatures, Benefits \u0026amp; Clinical Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRectal catheter with balloon—single-use safety for patient protection, reducing infection risks.\u003c\/li\u003e\n\u003cli\u003eNon-latex composition, ideal for sensitive patients or those with allergies.\u003c\/li\u003e\n\u003cli\u003e400mL capacity allows precise rectal ballooning and pressure feedback in standard testing protocols.\u003c\/li\u003e\n\u003cli\u003eOptimized tubing for easy intubation, minimizing discomfort with each rectal tube balloon placement.\u003c\/li\u003e\n\u003cli\u003eExternal depth markings for accurate, repeatable deployment of the anorectal balloon catheter.\u003c\/li\u003e\n\u003cli\u003eCross-compatible with solid-state and water-perfused motility equipment.\u003c\/li\u003e\n\u003cli\u003eDesigned for routine balloon expulsion tests and rectal ballooning biofeedback.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eClinical Use Cases:\u003c\/strong\u003e\u003cbr\u003eEffective for rectal ballooning procedures, expulsion testing, and biofeedback therapy—supporting patients with chronic constipation, functional GI disorders, or pelvic floor dysfunction.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2 id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Name\u003c\/td\u003e\n\u003ctd\u003eAnorectal Balloon Catheter (Rectal Catheter with Balloon) SR1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalloon Volume\u003c\/td\u003e\n\u003ctd\u003e400 mL \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eNon-latex \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsability\u003c\/td\u003e\n\u003ctd\u003eSterile, single-use - Filled with air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTubing\u003c\/td\u003e\n\u003ctd\u003eEasy intubation, marked for placement \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eSolid-state \u0026amp; water-perfused systems \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2 id=\"ordering-sku--regulatory\"\u003eOrdering, SKU \u0026amp; Regulatory\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSKU: SR1B\u003c\/li\u003e\n\u003cli\u003eSterile, single-use rectal ballooning device including stopcock and syringe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2 id=\"frequently-asked-questions\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is a rectal catheter with balloon used for?\u003c\/strong\u003e\u003cbr\u003eIt is designed for rectal ballooning and expulsion testing—providing both diagnostic feedback and therapeutic options in colorectal motility clinics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the anorectal balloon catheter inserted?\u003c\/strong\u003e\u003cbr\u003eThe specialized tubing and depth markers allow smooth, accurate placement for all rectal ballooning procedures.\u003c\/p\u003e\n\u003ch2\u003eCPT Codes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPT 91122:\u003c\/strong\u003e\u003cbr\u003eUsed for gastrointestinal imaging, pressure measurement, and manometric studies involving a manometer to measure rectal and anal sphincter contraction as part of anorectal expulsion or manometry testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPT 90901:\u003c\/strong\u003e\u003cbr\u003eDefined as “biofeedback training by any modality,” this code is an established part of the medicine services\/procedures set. It is appropriate for billing biofeedback including modalities like EMG, thermal, or EEG when not performed in conjunction with psychotherapy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional CPT codes that may be relevant for billing anorectal function assessment and biofeedback procedures include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e91120:\u003c\/strong\u003e Rectal sensation, tone, and compliance test (response to graded balloon distention), which is appropriate when performing rectal ballooning or compliance\/sensitivity testing in addition to or separate from manometry\/expulsion.\u003ca href=\"https:\/\/www.bhnco.com\/Resources\/anorectal-manometry-useful-terms.html\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90912:\u003c\/strong\u003e Biofeedback training, perineal muscles (including EMG and\/or manometry), initial 15 minutes, when performed one-on-one by a physician or qualified health professional; often used if a time-based, direct supervision is required.\u003ca href=\"https:\/\/motilitysociety.org\/billing-and-coding-information\/\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90913:\u003c\/strong\u003e Each additional 15 minutes of biofeedback training as above (used in conjunction with 90912 if session lasts longer than 15 minutes).\u003ca href=\"https:\/\/motilitysociety.org\/billing-and-coding-information\/\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e51784:\u003c\/strong\u003e Electromyography (EMG) studies of the anal or urethral sphincter, which may be performed as part of comprehensive pelvic floor assessments.\u003ca href=\"https:\/\/www.bhnco.com\/Resources\/anorectal-manometry-useful-terms.html\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e76872:\u003c\/strong\u003e Ultrasound, transrectal, sometimes used in complex cases to further characterize anatomy or guide therapy.\u003ca href=\"https:\/\/motilitysociety.org\/billing-and-coding-information\/\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e91117:\u003c\/strong\u003e Colon motility (manometric) study with extended recording, in rare, complex cases or as required for assessing more expansive motility concerns.\u003ca href=\"https:\/\/motilitysociety.org\/billing-and-coding-information\/\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Billing Advice\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli\u003eCPT 91122 and 91120 can sometimes both be billed if distinct manometry and compliance\/sensitivity testing are performed and documented separately, but always review local payer policies to ensure correct billing practices.\u003ca href=\"https:\/\/www.asge.org\/home\/resources\/publications\/practical-solutions\/practical-solutions-january-asge-answers-your-coding-questions\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePair appropriate ICD-10 diagnosis codes such as K59.00–K59.09 (constipation), R15.0–R15.9 (fecal incontinence), K59.4 (anal spasm), and others relevant to functional bowel disorders.\u003ca href=\"https:\/\/www.laborie.com\/education\/reimbursement\/\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnsure clinical and procedural notes clearly document medical necessity, test parameters, distinct time intervals, and modality, especially for time-based codes like 90912\/90913.\u003ca href=\"https:\/\/motilitysociety.org\/billing-and-coding-information\/\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mui Scientific","offers":[{"title":"10\/bx \/ Anorectal Balloon Catheters","offer_id":45031623950472,"sku":"SR1B","price":500.0,"currency_code":"USD","in_stock":true},{"title":"ea \/ Anorectal Balloon Catheters","offer_id":45067545411720,"sku":"SR1B-EA","price":60.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/4094\/5544\/files\/Expulsion-Balloon-Catheter_5311_c608ff04-ecad-476d-be9f-281cc2247249.jpg?v=1776912495"}],"url":"https:\/\/www.cincymed.com\/collections\/anorectal-manometry-balloon-expulsion-test.oembed","provider":"CincyMed","version":"1.0","type":"link"}